DC GFCI Thermostat

DC GFCI Thermostat

DGT

The DGT is a heating floor controller combined with a ground fault interrupting circuit. It uses a temperature sensor and an external power contactor (DGT1) or an internal fully protected SSR (DGT2) to regulate floor temperature. In case of a ground fault, the DGT will automatically disconnect the power and activate the fault status output.

Download the technical sheet

DGT1 shown

Highlights

- High voltage source/load up to 2500VDC, 50A
- Isolated current sensing with automatic sensor verification
- 4 factory set leakage thresholds (30, 50, 70, 90 mADC)
- Programmable temperature setpoint
- Operating temperature range of -40°C to 70°C
- DGT2 has an incorporated fully protected SSR switch

Service Proven

New product series

Models & features

Part Number Base

DGT1
DGT2

Operating Voltage

37.5VDC
37.5VDC

Max Source/Load Voltage (PD2)

3500VDC
825VDC

Max Source/Load Voltage (PD3)

2500VDC
825VDC

Max Source/Load Current

50A
13A

Current Leakage Threshold

F
F

Width X Height X Depth
3.00” X 8.29” X 5.00”

X
X

Part Number Base

DGT1
Operating Voltage : 37.5VDC
Max Source/Load Voltage (PD2) : 3500VDC
Max Source/Load Voltage (PD3) : 2500VDC
Max Source/Load Current : 50A
Current Leakage Threshold : F
Width X Height X Depth
3.00” X 8.29” X 5.00” :
X

Part Number Base

DGT2
Operating Voltage : 37.5VDC
Max Source/Load Voltage (PD2) : 825VDC
Max Source/Load Voltage (PD3) : 825VDC
Max Source/Load Current : 13A
Current Leakage Threshold : F
Width X Height X Depth
3.00” X 8.29” X 5.00” :
X

X = Included, O = Optional, F = Factory Configurable