120V Single Outlet Box with Auto-Resettable Breaker

120V Single Outlet Box with Auto-Resettable Breaker

SOB

Transtech’s Single Outlet Box (SOB) series is
specially designed for railroad applications. A
WAGO connector is provided at the back of unit
for fast installation.
SOB2.0 includes a 2A auto-resettable breaker. In
case of an overload, the circuit will automatically
open without need for fuse replacement or
manual reset.
SOB20 et SOB15 have a maximum current
rating of 20A or 15A respectively. However, they
are not internally current-limited. An
appropriate breaker or fuse must be installed in
series with these outlets.

Download the technical sheet

SOB2.0-H shown

Highlights

- Single 120VAC outlet
- Surge suppression to protect passenger’s apparatus
- Overload status indicator on the front panel
- Multiple orientation options

Service Proven

SOB2.0-H

OEM : Alstom

Transit Authority : Caltrain

Project : BI-LEVEL

San Francisco

Models & features

Part Number Base

SOB2.0-H
SOB2.0-V
SOB20-H
SOB20-V
SOB15-H
SOB15-V

Operating Voltage

120VAC
120VAC
120VAC
120VAC
120VAC
120VAC

Maximum Output current

2A
2A
20A
20A
15A
15A

Internally Limited Current (Auto-Resettable Breaker Option)

X
X
-
-
-
-

Mount Orientation

Horizontal
Vertical
Horizontal
Vertical
Horizontal
Vertical

Length X Height X Depth 5.55” X 2.28” X 2.22”

X
X
X
X
X
X

Part Number Base

SOB2.0-H
Operating Voltage : 120VAC
Maximum Output current : 2A
Internally Limited Current (Auto-Resettable Breaker Option) : X
Mount Orientation : Horizontal
Length X Height X Depth 5.55” X 2.28” X 2.22” : X

Part Number Base

SOB2.0-V
Operating Voltage : 120VAC
Maximum Output current : 2A
Internally Limited Current (Auto-Resettable Breaker Option) : X
Mount Orientation : Vertical
Length X Height X Depth 5.55” X 2.28” X 2.22” : X

Part Number Base

SOB20-H
Operating Voltage : 120VAC
Maximum Output current : 20A
Internally Limited Current (Auto-Resettable Breaker Option) : -
Mount Orientation : Horizontal
Length X Height X Depth 5.55” X 2.28” X 2.22” : X

Part Number Base

SOB20-V
Operating Voltage : 120VAC
Maximum Output current : 20A
Internally Limited Current (Auto-Resettable Breaker Option) : -
Mount Orientation : Vertical
Length X Height X Depth 5.55” X 2.28” X 2.22” : X

Part Number Base

SOB15-H
Operating Voltage : 120VAC
Maximum Output current : 15A
Internally Limited Current (Auto-Resettable Breaker Option) : -
Mount Orientation : Horizontal
Length X Height X Depth 5.55” X 2.28” X 2.22” : X

Part Number Base

SOB15-V
Operating Voltage : 120VAC
Maximum Output current : 15A
Internally Limited Current (Auto-Resettable Breaker Option) : -
Mount Orientation : Vertical
Length X Height X Depth 5.55” X 2.28” X 2.22” : X

X = Included, O = Optional, F = Factory Configurable